<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-03 02-03-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 58 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 54 kHz 14034 6,0068
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,2 dBr 2,46 dBr 3,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 54 kHz MIN: 16 kHz % above 76 kHz: 6,0068 Acquired: 2024/08/03 2.02.11 Total samples: 14034 Equivalent time: 0:11:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 3,5 dBr MIN: 1,2 dBr AVE: 2,46 dBr % above 12,2 dBr: 0,0 Last value: 3,2 dBr (2024/08/03 2.02.10) 01.48 01.50 01.52 01.54 01.56 01.58 02.00 02.02 -1 0 1 2 3 4 Pm [dBr]